Analysis of electric field strength propagating underneath the 132 kV overhead power line

B. Alhaj, Reyad Mohamed (2013) Analysis of electric field strength propagating underneath the 132 kV overhead power line. Masters thesis, Universiti Tun Hussein Onn Malaysia.

[img]
Preview
Text
24p REYAD MOHAMED B.ALHAJ.pdf

Download (1MB) | Preview
[img] Text (Copyright Declaration)
REYAD MOHAMED B.ALHAJ COPYRIGHT DECLARATION.pdf
Restricted to Repository staff only

Download (235kB) | Request a copy
[img] Text (Full Text)
REYAD MOHAMED B.ALHAJ WATERMARK.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

This research presents the electric field strength propagating of 132 kV overhead power lines. In the calculation of the electric field with the charge simulation method it is difficult to judge the magnitude of the field strength in the area, especially the accuracy of the field strength. One of the applications of electric field strength is its implementation in radio planning process as an accurate estimation of propagating power loss. This provides a way for determination of the electric field strength carrier-to-interference (C/I) ratio and all other parameters necessary for proper radio design, to know the effects of electric field on human health. 132 kV overhead lines have selected to be the case of study in this project because this type used to be in the area which near the residential area that nowadays mostly being occupied with commercial, offices, building, housing estates etc. The objectives of this study to define the possible method enabling calculating the electric field strength underneath the 132 kV line, another objective is to calculate the electric field strength propagated by the 132 kV line at some points above the ground level, and analysis the finding results with the guideline electric limits public and occupational exposure as defined in the international standard. The work in this project has used Excel and Visio to discuss the analysis before getting results it has done calculate the conductor sag, conductor clearance and conductor distances for each level. The study has divided to three cases the first case analysis the electric field for single conductor, the second case analysis the electric for two conductors, the third case analysis the electric field for all six conductors, all those analyse are on 1 m and 2 m above the ground and its vicinity on 30 m left and 30 m right from the centre line. This research has compared the finding results with the EMF exposure standards with general public and occupational exposure limits the results were less than standard limits for both cases of study 1m and 2m above the ground on 30m form center the line. The results of this research shown the electric field in area on 1m and 2m above the ground at 30m left and right from center the line is enough safe.

Item Type: Thesis (Masters)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power
Divisions: Faculty of Electrical and Electronic Engineering > Department of Electrical Engineering
Depositing User: Mrs. Sabarina Che Mat
Date Deposited: 31 Oct 2021 01:47
Last Modified: 31 Oct 2021 01:47
URI: http://eprints.uthm.edu.my/id/eprint/2114

Actions (login required)

View Item View Item