Transient response analysis for DC-DC boost converter

Libau , Charles Muling (2012) Transient response analysis for DC-DC boost converter. Masters thesis, Universiti Tun Hussein Onn Malaysia.

[img]
Preview
PDF
1024Kb

Abstract

DC-DC Boost Converter and Hybrid Posicast Controller is developed and simulated using MATLAB Simulink software. DC-DC Boost converter has a very high overshoot and a very high settling time which produce oscillated output response. In order to overcome this weakness, Hybrid Posicast Controller is used in order to regulate the output voltage to a desire value. Hybrid Posicast Controller operated within the feedback loop of the system. Transfer function of DC-DC Boost Converter are derived and Posicast elements of d and Td can be calculated directly from the transfer function. Single gain, K is used in order to eliminate the overshoot and minimize the settling time. Simulation results show that Hybrid Posicast Controller effectively regulate the output voltage to a desire value even though load resistance and duty cycle have been changed with a various values. DC-DC Boost Converter using Posicast Controller has an excellent performance to overcome unregulated input voltage, eliminate overshoot and minimize the settling time.

Item Type:Thesis (Masters)
Subjects:T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7800-8360 Electronics
ID Code:2916
Deposited By:Normajihan Abd. Rahman
Deposited On:08 Nov 2012 10:52
Last Modified:08 Nov 2012 10:52