Md Noor, Nurazuwa (2006) Comparative study on structural behaviour of bonded and unbonded post-tensioned beam. Masters thesis, Universiti Putra Malaysia.
|
Text
24p NURAZUWA MD NOOR.pdf Download (16MB) | Preview |
Abstract
In this study, a simple computer program are written using FOTRAN 90 to investigate the behavior of simply supported beam constructed with straight tendon which are subjected to three different load cases. Considering the same stresses applied, beam subjected to loading at one third span shows a less deflection than other load cases. Behavior due to the deflection of bonded tendon gave better performance than unbonded tendon. However, beams with larger span-to-depth ratio would require deviators in case of external prestressing to achieve the desired performance. Parabolic and trapezoidal tendon allows the prestressed beam to carry heavier loads because of the balancing effects of the vertical component of the prestressing deflected tendon. Hence it will required less prestressing force at the mid span compared with the force required in the straight tendon.
Item Type: | Thesis (Masters) |
---|---|
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TA Engineering (General). Civil engineering (General) > TA630-695 Structural engineering (General) |
Depositing User: | Mrs. Sabarina Che Mat |
Date Deposited: | 30 May 2022 00:45 |
Last Modified: | 30 May 2022 00:45 |
URI: | http://eprints.uthm.edu.my/id/eprint/7088 |
Actions (login required)
View Item |