Signal quality measures for pulse oximetry through waveform morphology analysis

Sukor, J. Abdul and Redmond, S. J. and Lovell, N. H. (2011) Signal quality measures for pulse oximetry through waveform morphology analysis. Physiological Measurement, 32. pp. 369-384. ISSN 0967-3334

[img] Text
J5712_6ce2a472a70b9671ed934dee12ca22ec.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Pulse oximetry has been extensively used to estimate oxygen saturation in blood, a vital physiological parameter commonly used when monitoring a subject’s health status. However, accurate estimation of this parameter is difficult to achieve when the fundamental signal from which it is derived, the photoplethysmograph (PPG), is contaminated with noise artifact induced by movement of the subject or the measurement apparatus. This study presents a novel method for automatic rejection of artifact contaminated pulse oximetry waveforms, based on waveform morphology analysis. The performance of the proposed algorithm is compared to a manually annotated gold standard. The creation of the gold standard involved two experts identifying sections of the PPG signal containing good quality PPG pulses and/or noise, in 104 fingertip PPG signals, using a simultaneous electrocardiograph (ECG) signal as a reference signal. The fingertip PPG signals were each 1 min in duration and were acquired from 13 healthy subjects (10 males and 3 females). Each signal contained approximately 20 s of purposely induced artifact noise from a variety of activities involving subject movement. Some unique waveform morphology features were extracted from the PPG signals, which were believed to be correlated with signal quality. A simple decision-tree classifier was employed to arrive at a classification decision, at a pulse-by-pulse resolution, of whether a pulse was of acceptable quality for use or not. The performance of the algorithm was assessed using Cohen’s kappa coefficient (κ), sensitivity, specificity and accuracy measures. A mean κ of 0.64 ± 0.22 was obtained, while the mean sensitivity, specificity and accuracy were 89 ± 10%, 77 ± 19% and 83 ± 11%, respectively. Furthermore, a heart rate estimate, extracted from uncontaminated sections of PPG, as identified by the algorithm, was compared with the heart rate derived from an uncontaminated simultaneous ECG signal. The mean error between both heart rate readings was 0.49 ± 0.66 beats perminute (BPM), in comparison to an error value observed without using the artifact detection algorithm of 7.23 ± 5.78 BPM. These results demonstrate that automated identification of signal artifact in the PPG signal through waveform morphology analysis is achievable. In addition, a clear improvement in the accuracy of the derived heart rate is also evident when such methods are employed.

Item Type: Article
Uncontrolled Keywords: Pulse oximetry; photoplethysmograph; artifact; morphology.
Subjects: T Technology > T Technology (General)
Depositing User: Mr. Abdul Rahim Mat Radzuan
Date Deposited: 08 Nov 2022 01:37
Last Modified: 08 Nov 2022 01:37