Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment

Noraini, Nor Mohd Razif (2015) Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment. Diploma thesis, Universiti Tun Hussein Onn Malaysia.

[img] Text (Copyright Declaration)
NOR MOHD RAZIF NORAINI COPYRIGHT DECLARATION.pdf
Restricted to Repository staff only

Download (669kB) | Request a copy
[img]
Preview
Text (24 pages)
24p NOR MOHD RAZIF NORAINI.pdf

Download (1MB) | Preview
[img] Text (Full Text)
NOR MOHD RAZIF NORAINI WATERMARK.pdf
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

Indoor Air Quality (IAQ) is a part of Building Environment. Nowadays, the construction of new building took place over the world. Upon new building occupancy, a lot of indoors material was used without IAQ concern. This study has been conducted in a new constructed building of the National Institute of Occupational Safety and Health (NIOSH) Malaysia. The goal of the study is to monitor on the level of IAQ parameters including chemical and physical parameters within four consequent stages which are before furniture install, after furniture install and during one and three month occupancy. The indoor parameters have been measured consist of nine parameters including of Carbon Dioxide (CO2), Carbon Monoxide (CO), Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM10), Ozone, Relative Humidity (RH), Temperature and Air Movement. The interaction between Malaysian and international standard was referred and utilized in collecting the data and analyzing of the findings. There was a significant correlation between the high values of RH, Formaldehyde and PM10 where (r 0.324, p <0.05), (r 0.344, p <0.05) and (r 0.319, p<0.05) with extension of phases of new building occupancy respectively. This study established significant different on Formaldehyde and Particulate Matter (PM10) concentration level as go along with the building occupancy. These finding indicated that furniture and fittings, indoor materials and human population has a potential sources of indoor air contaminants. It is recommended that the management should be aware to their indoor air status to protect the occupant from the risk of unwanted exposure especially during the early stage of building occupancy. Finally this research has fully supported the Malaysian need to formulate of future guideline on IAQ commissioning and maintenance of new building occupancy.

Item Type: Thesis (Diploma)
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD878-894 Special types of environment, Including soil pollution, air pollution, noise pollution
Divisions: Faculty of Mechanical and Manufacturing Engineering > Department of Mechanical Engineering
Depositing User: Mrs. Nur Nadia Md. Jurimi
Date Deposited: 04 Oct 2021 01:34
Last Modified: 04 Oct 2021 01:34
URI: http://eprints.uthm.edu.my/id/eprint/1651

Actions (login required)

View Item View Item