Force control for one degree of freedom haptic device using PID Controller

Mohamad Husni, Nur Amirah (2019) Force control for one degree of freedom haptic device using PID Controller. Masters thesis, Universiti Tun Hussein Onn Malaysia.

[img]
Preview
Text
24p NUR AMIRAH MOHAMAD HUSNI.pdf

Download (727kB) | Preview
[img] Text (Copyright Declaration)
NUR AMIRAH MOHAMAD HUSNI COPYRIGHT DECLARATION.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy
[img] Text (Full Text)
NUR AMIRAH MOHAMAD HUSNI WATERMARK.pdf
Restricted to Registered users only

Download (2MB) | Request a copy

Abstract

Haptics has been used as an additional feedback to increase human experience to the environment over years and its application has been expanded into education, manufacturing and medical. The most developed haptic devices are for rehabilitation purpose. The rehabilitation process usually depends on the physiotherapist. But, it requires repetitive movements for long-term rehabilitation, thus haptic devices are needed. Most of the rehabilitation devices are included with haptic feedback to enhance therapy exercise during the rehabilitation process. However, the devices come with multiple degrees of freedom (DOF), complex design and costly. Rehabilitation for hand movement such as grasping, squeezing, holding and pinching usually does not need an expensive and complex device. Therefore, the goal of this project is to make an enhancement to One DOF Haptic Device for grasping rehabilitation exercise. It is improved to perform a force control mechanism with few types of conventional controller which are Proportional (P) controller, Proportional-Integral (PI) controller, Proportional-Derivative (PD) controller and Proportional-Integral-Derivative (PID) controller. The performance of the haptic device is tested with different conventional controller to obtain the best proposed controller based on the lowest value of the Mean Square Error (MSE). The results show that PID Controller is the most suitable for the proposed device with Proportional gain (Kp), Integral gain (Ki), Derivative gain (Kd) are 1.3, 0.01 and 0.2 respectively. The force control mechanism can imitate the training motion of grasping movement for the patient.

Item Type: Thesis (Masters)
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ212-225 Control engineering systems. Automatic machinery (General)
Divisions: Faculty of Electrical and Electronic Engineering > Department of Electrical Engineering
Depositing User: Mrs. Sabarina Che Mat
Date Deposited: 11 Aug 2021 04:55
Last Modified: 11 Aug 2021 04:55
URI: http://eprints.uthm.edu.my/id/eprint/621

Actions (login required)

View Item View Item