Thermal Comfort in a Tropical Climate: Case Study of the Cafeteria in Student Residential College, UTHM Pagoh Branch Campus

Mohamad Sahimi, Nur Nabilah and Mustafa, Mohd Syafiq Syazwan and Muslim, Rahmat and Roslan, Nurul Hidayah and Yusop, Fatimah and Hariri, Azian and Zakaria, Anies Faziehan and Abd Latif, Muhamad Faiz and Kabrein, Hashim and Nur Yunus, Faizal Amin (2024) Thermal Comfort in a Tropical Climate: Case Study of the Cafeteria in Student Residential College, UTHM Pagoh Branch Campus. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 114 (2). pp. 165-187. ISSN 2289-7879

[img] Text
J17652_606e4e31ea6fe1a738796e4c3eac2781.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Thermal comfort is important for buildings, especially in tropical climates. The issue of increasing indoor temperature is influenced by various factors that cause occupants to face thermal discomfort in cafeterias that uses both mechanical and natural ventilation systems. This study aims to determine the perception of occupants and evaluate parameter variations of thermal comfort in the cafeteria of Pagoh Campus Residential College, UTHM Pagoh Branch Campus. This study was conducted through the measurements of subjective and physical parameters. Data collection is carried out in two days, which are weekdays and weekends. This study uses some parameters variation which are thermal sensation vote index (TSV), predicted mean vote index (PMV), predicted percentage of dissatisfaction (PPD), operative temperature (To) and neutral operative temperature (Tneutop) to determine the thermal comfort conditions in the cafeteria. The results shows that the average values of air temperature, mean radiation temperature, relative humidity and air velocity from environmental measurements were 30.2 °C, 30.6 °C, 66% and 0.1 m/s respectively. In addition, PMV and PPD values were 2.0 and 76% from environmental measurements, while 1.36 and 43% from questionnaires. For To and Tneutop, the average values obtained are 30.4 °C and 28.6 °C. Furthermore, the findings showed that only the morning session was in the acceptable operative temperature range and complied with ASHRAE Standard 55 for both the 80% and 90% acceptability limits. At the end of the study, it was found that the values from the thermal environment measurements and surveys exceeded those recommended by ASHRAE Standard 55. This concluded that the quality of the occupants’ environment in the cafeteria is outside the satisfactory thermal comfort level.

Item Type: Article
Uncontrolled Keywords: Thermal comfort; natural ventilation; tropical climate
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Engineering Technology > FTK
Depositing User: Mr. Mohamad Zulkhibri Rahmad
Date Deposited: 19 Jun 2024 03:55
Last Modified: 19 Jun 2024 03:55
URI: http://eprints.uthm.edu.my/id/eprint/11169

Actions (login required)

View Item View Item