The influence of particle size towards the resistivity and chargeability value for groundwater investigation interpretation

Abd Malik, Ahmad Khairul (2021) The influence of particle size towards the resistivity and chargeability value for groundwater investigation interpretation. Masters thesis, Universiti Tun Hussein Malaysia.

[img]
Preview
Text
24p AHMAD KHAIRUL ABD MALIK.pdf

Download (3MB) | Preview
[img] Text (Copyright Declaration)
AHMAD KHAIRUL ABD MALIK COPYRIGHT DECLARATION.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy
[img] Text (Full Text)
AHMAD KHAIRUL ABD MALIK WATERMARK.pdf
Restricted to Registered users only

Download (4MB) | Request a copy

Abstract

Electrical resistivity tomography is a non-destructive method of groundwater surveying where the current is being injected into the ground and the value of the subsurface resistivity and chargeability were determined. One of the major problems in groundwater surveying is the interpretation of the groundwater aquifer under saturated condition. The overlapping resistivity and chargeability value under a saturated condition is a major concern in groundwater aquifer interpretation. In this study, the effects of particle size and the interrelationship between the different particle sizes were assessed towards the resistivity and chargeability value. There were 17 samples used in this study ranges from gravel, sand, silt and clay sizes. The materials used to conduct the testing were granitic rock and river sand. Quartz and kaolinite dominated samples were used for the silt and clay sample. The device used for the experiment is Terrameter LS 2 to conduct the resistivity and induced polarization tests. The electrical testing follow the ASTM G57 and ASTM G187/AASHTO T-288 standards for the soil box with volume of 270 cm and soil cylinder with volume of 2714 cm 3 respectively. The resistivity value for the gravel ranges from 177 Ωm at its highest to 128 Ωm at its lowest. The resistivity value for the sand ranges from 121 Ωm at its highest to 86 Ωm at its lowest. The resistivity value of the two silt and clay samples were 37 Ωm and 56 Ωm at the point of liquid limit. The chargeability value for the gravel ranges from 5.6 ms to 7.9 ms with decreasing particle size. The highest chargeability value for sand is 12.3 ms and the lowest is 2.0 ms. The silt and clay samples chargeability were 1.7 ms and 1.2 ms, respectively. The resistivity and chargeability for water used in this study were 101.7 Ωm and 0.41 ms. This study helps in clarifying the effect of particle size for resistivity and chargeability value as the larger particle size increases the resistivity value and decreases the chargeability value of water due to porosity and improve the understanding of the electrical resistivity tomography for groundwater investigation interpretation.

Item Type: Thesis (Masters)
Subjects: Q Science > QC Physics
T Technology > T Technology (General)
Q Science > QC Physics > QC501-766 Electricity and magnetism
Divisions: Faculty of Applied Science and Technology > Department of Physics and Chemistry
Depositing User: Mrs. Sabarina Che Mat
Date Deposited: 05 Feb 2022 07:27
Last Modified: 05 Feb 2022 07:27
URI: http://eprints.uthm.edu.my/id/eprint/6437

Actions (login required)

View Item View Item